Hydraway 2000 Physical Properties
Product | Test Method | Typical Value |
---|---|---|
Compressive Strength | ASTM D-695/16211 | 11,400 PSF |
Flow Rate At 1,500 PSF | ASTM D-471622 | 21 GPM/ft-width |
Peel Strength3 | ASTM D-1876 | 50 lbs/ft-width |

Hydraway 2000 Dimensions
See our PDF for the details and dimensions of Hydraway 2000.
Fabric (4.5 oz.)
Product | Test Method | Typical Value |
---|---|---|
Elongation | ASTM D-4632-91 | 50% |
Grab Tensile | ASTM D-4632-91 | 120 lbs |
Puncture Strength | ASTM D-4833-00 | 65 lbs |
Mullen Burst Strength | ASTM D-3756-87 | 225 psi |
Trapezoidal Tear | ASTM D-4533-91 | 50 lbs |
Wide width Tensile | ASTM D-4595 | 50 lbs/in |
UV Resistance (500 hours) | ASTM D-4355-02 | 70% |
Permitivity | ASTM D-4491-99A | 1.8 sec |
Permeability | ASTM D-4751-99A4 | .21 cm/sec |
Flow Rate | ASTM D-4491 | 135 gal/min/ft24 |
AOS (EOS) | ASTM D-4751-99A | 70 US Standard Sieve |

Roll Dimensions
Width | 6, 12, 18, or 24 inches – Other sizes available upon request |
Length | 150 feet – up to 550′ available upon request |
Footnotes
1. Modified – an existing ASTM test was modified since a recognized test method had not been established for this type of product at time of testing. |
2. Gradient of 0.1 |
2. Gradient of 0.1 |
4. Values shown are in weaker principal direction. Minimum average roll values are calculated as the typical minus two standard deviations. Statistically, it yields a 97.7% degree of confidence that any samples taken from quality assurance testing will exceed the value reported. |
Contact Us Today for a Quote
Navigation
Contact Info
St. Louis Office & Warehouse
8250 Bunkum Rd
Caseyville, IL 62232
Michigan Office & Warehouse
Our Blog
- How to Drain Water Away From Foundations January 25, 2021
- Why Do Drainage Material Suppliers Trust Hydraway? January 15, 2021
- Residential Yard Drainage Project Case Study December 28, 2020